small gas inlet system for orbital mass-spectrometer calibrations

Alphonsa Smith

small gas inlet system for orbital mass-spectrometer calibrations

  • 202 Want to read
  • 20 Currently reading

Published by National Aeronautics and Space Administration, Scientific and Technical Information Office, for sale by the National Technical Information Service in [Washington], Springfield, Va .
Written in English

    Subjects:
  • Pressure gages,
  • Mass spectrometry,
  • Calibration

  • Edition Notes

    StatementAlphonsa Smith and Richard E. Stell ; Langley Research Center, Hampton, Virginia
    SeriesNASA technical paper ; 1170
    ContributionsStell, Richard E , joint author, United States. National Aeronautics and Space Administration. Scientific and Technical Information Office, Langley Research Center
    The Physical Object
    Pagination30 p. :
    Number of Pages30
    ID Numbers
    Open LibraryOL14931980M

    The Thermo Scientific Plus stable isotope ratio mass spectrometer provides a flexible and open platform for the connection of inlet systems and preparation devices for smallest amounts of sample in IRMS. Plus 10 kV Isotope Ratio Mass Spectrometer; Kiel IV Carbonate Device. The Benchtop Mass Spectrometer is a compact versatile gas analysis system for sampling gases over a wide range of pressures, from high vacuum up to and beyond atmospheric pressure. The analyzer and inlet system can be removed from the frame and placed up to 10 feet from the pumping station using the included cable and vacuum hose.


Share this book
You might also like
postage stamps of Great Britain

postage stamps of Great Britain

HUMAN FACTORS OF IN-VEHICLE DRIVER INFORMATION SYSTEMS: AN EXECUTIVE SUMMARY... PUBLICATION NO. FHWA-RD-95-014... U.S. DEPARTMENT OF TRANS.

HUMAN FACTORS OF IN-VEHICLE DRIVER INFORMATION SYSTEMS: AN EXECUTIVE SUMMARY... PUBLICATION NO. FHWA-RD-95-014... U.S. DEPARTMENT OF TRANS.

The state and revolution

The state and revolution

military medical officer and the Geneva Conventions

military medical officer and the Geneva Conventions

Alien deep

Alien deep

Xwd Puz Bk 127 P

Xwd Puz Bk 127 P

Registration and inquiry manual.

Registration and inquiry manual.

Introduction to New Zealand banking law

Introduction to New Zealand banking law

study of dental public health services in New Zealand.

study of dental public health services in New Zealand.

Exemption clauses and implied obligations in contracts

Exemption clauses and implied obligations in contracts

investigation into integration innovation for children and young people with mild learning difficulties.

investigation into integration innovation for children and young people with mild learning difficulties.

Intro to Management

Intro to Management

Drills and dances for the grades,

Drills and dances for the grades,

Prehistoric rock paintings and engravings of Zambia

Prehistoric rock paintings and engravings of Zambia

small gas inlet system for orbital mass-spectrometer calibrations by Alphonsa Smith Download PDF EPUB FB2

A gas inlet system is described for generating precise gas pressures that are to be used as calibration references for the mass spectrometers aboard the dual air density Explorer satellites.

This gas inlet system was developed as an inflight calibration technique in which a known amount of onboard gas is released in the satellite cavity and is detected by the mass spectrometer.

This gas inlet system was developed as an inflight calibration technique in which a known amount of onboard gas is released in the satellite cavity and is detected by the mass spectrometer. Although several flight mass spectrometer experiments have been proposed, none make use of the inflight calibration technique described in this report.

A gas inlet system is described for generating precise gas pressures that are to be used as calibration references for the mass spectrometers aboard the dual air density (DAD) Explorer satellites. This gas inlet system was devel­ oped as an in-flight calibration technique in which a known amount of onboard.

A small gas inlet system for orbital mass-spectrometer calibrations / ([Washington]: National Aeronautics and Space Administration, Scientific and Technical Information Office ; Springfield, Va.: For sale by the National Technical Information Service, ), by Alphonsa Smith, Richard E.

Stell, Langley Research Center, and United States. Mass Spectrometers for Gas Analysis | 3 The Hiden HPR R&D specialist gas analysis system is a benchtop mass spectrometer for the monitoring of evolved gases and vapours.

A triple filter mass spectrometer is included providing improved resolution and abundance sensitivity with an ultimate detection limit of 5 ppb subject to spectral Size: 2MB. ARCHIVES OF BIOCHEMISTRY AND BIOPHYSICS() A Mass Spectrometer Inlet System for Sampling Gases Dissolved in Liquid Phases1 GEORGE HOCH AND BESSEL KOK From RIAS, Baltimore, Maryland Received Novem A mass spectrometer inlet system has been devised which permits continuous sampling of gases dissolved in liquid Cited by: gas (CO) is loaded, and the ECN gas is run periodically to maintain precise calibration over the range of δ13C values measured (‰ to –53‰).

2) VG D Messr Griesheim supplied the H2 reference gas used in this mass spectrometer. This is checked on days of analysis using Norwich Tap Water (NTW) reduced using Indiana Size: 13KB. Diagnosing and Resolving Mass Spec Problems April NOTE: It is not my intent to try to turn the readers into mass spec service technicians.

I provide this information to help educate the readers. I realize that it’s a full time job just to run a GC/MS-what with tuning, calibrating, running samples, reviewing data, etc.

Questions on Instrumental Methods of Analysis 1. Which one of the following techniques can be used for the detection in a liquid The sample molecules are converted into ions in the inlet system of the mass spectrometer A precise analytical measurement will always have a small relative standard deviation.

(3) If an analysis is File Size: KB. An essential element of a quadrupole mass spectrometer is therefore a suitable gas inlet system for the particular application.

Various pressure reducing procedures are used, depending on the pressure gradient in question. Gas mixtures should be admitted to the mass spectro-meter without de-mixing if possible.

The idea of using a membrane inlet system for the monitoring of dissolved gases was soon picked up by physiologists who developed small membrane-covered catheters for in vivo blood gas analysis. By mounting the catheter in the arteries or veins, physiologists were able to study the kinetics behind gas uptake and by: 1.

Calibration effects during natural gas analysis using a quadrupole mass spectrometer P. Turner, S. Taylor, E. Clarke, C. Harwood, K. Cooke, H. Frampton Quadrupole mass spectrometry (QMS) is regularly used for online monitor-ing of gaseous systems.

With the advent of miniature QMS, it. Inlet system - three requires are: • (1) that sample must be in the vapour phase prior to ionisation. • (2) that sample does not suffer thermal decomposition during the vaporisation process. • (3) that during admission of the sample, the pressure inside the mass spectrometer us kept as low as Size: 4MB.

systems consist of an inlet system, a PrismaPlus mass spectrometer, a dry diaphragm vacuum pump and a HiPace turbopump. They feature a heated, tempe-rature-regulated gas inlet system and, by comparison with such competing methods as FTIR and IR, are suitable for qualitative and quantitative analysis of gases.

The unitsFile Size: KB. Calibration effects during natural gas analysis using a quadrupole mass spectrometer Article (PDF Available) in TrAC Trends in Analytical Chemistry 23(4). 16 FIGURE REPRESENTING INSTRUMENTATION OF A MASS SPECTROMETER INLET SYSTEM: The selection of a sample inlet depends upon the sample and the sample matrix.

Most ionization techniques are designed for gas phase molecules so the inlet must transfer the analyte into the source as a gas phase molecule. If the analyte. A Novel Membrane Inlet Mass Spectrometer Method to Measure (NH4+)-N for Isotope-Enrichment Experiments in Aquatic Ecosystems Article (PDF Available) in Environmental Science and Technology   An "open-split" device allows equivalent inlet conditions for both standard gas and sample gas.

Continuous flow systems permit coupling of a gas chromatograph to a mass spectrometer for compound specific isotopic analysis.

Viscous flow systems allow high precision analyses, but require a relatively large sample size in order to ensure viscous. Data System Mass Detector Analyzer Vacuum System Source Inlet Region *More precisely mass spectrometry determines the mass of a molecule. **The mass to charge ratio (m/z) is used to describe ions observed in mass convention, m is the numerical value for the mass of the ion and z is the numerical value for the charge of the Size: KB.

Vacuum system A high vacuum is to be maintained. The inlet system is generally maintained at torr, the ion source at torr and analyzer tube at torr or as low as possible. Oil diffusion and mercury diffusion pumps are commonly used in different types of combination The MGA™ EC™ process mass spectrometer is a fixed magnetic sector analyzer that provides rapid, accurate and stable real-time analysis of up to 15 gas components in multiple gas streams.

Hardware configurable to provide both continuous and instantaneous readings of gas concentrations with less than 1 second response time for all components. Membrane inlet mass spectrometry is a tried-and-trusted technique for resolving dissolved gas species from liquid samples.

It is routinely employed in environmental monitoring applications such as the analysis of groundwater to quantify low-level pollutants, or recreational applications where disinfectant by-products (DBPs) could be harmful to the health and wellbeing of swimmers.

port liners and O-rings. Gas ballast the foreline pump. Every month Clean the split/splitless inlet vent line trap. Check for leaks (inlet and column connections). Every three months Replace gas cylinders (when below psig). Every six months Replace the foreline pump oil. Check, and if necessary, refill the calibration vial.

Every year. The mass spectrometer’s inlet system introduces a small sample into the ion source by using a flow-by capillary or a membrane.

The spectrometer’s design must ensure that the introduced sample is a true representation of the. 3 multi-stream samplers designed specifically for gas analysis mass spectrometers.

Continuous inlets have been used in the plant for process applications, and in the laboratory for research applications. Batch inlet: this is used when a limited amount. Membrane Inlet Gas Analyser. The MAXLG Membrane Inlet Mass Spectrometer Gas Analyser (MIMS) is a fully automated Quantitative Gas Analysis system with a temperature controlled Membrane Introduction Inlet for fast and repeatable analysis of gases and dissolved gases in liquids at the parts-per-trillion level.

Gas chromatography-mass spectrometry 2 Instrumentation The insides of the GC-MS, with the column of the gas chromatograph in the oven on the right. The GC-MS is composed of two major building blocks: the gas chromatograph and the mass spectrometer. The gas chromatograph utilizes a capillary column which depends on the column's dimensions.

Gas chromatography–mass spectrometry (GC-MS) is an analytical method that combines the features of gas-chromatography and mass spectrometry to identify different substances within a test sample.

Applications of GC-MS include drug detection, fire investigation, environmental analysis, explosives investigation, and identification of unknown samples, including that of. Calibration of an in situ membrane inlet mass spectrometer for measurements of dissolved gases and volatile organics in seawater.

Bell RJ(1), Short RT, van Amerom FH, Byrne RH. Author information: (1)College of Marine Science, University of South Florida, St PetersburgUSA. [email protected] by: oa-TOF mass spectrometer.

Ions produced in the source are electrostatically drawn through heated drying gas and then through a sampling capillary into the first stage of the vacuum system. Near the exit of the capillary is a metal skimmer with a small hole. Heavier ions with greater momentum pass through the skimmer aperture.

Most of the. The sample must first be introduced into the mass spectrometer (MS). These techniques vary a lot. The sample handling technique used in this study, described in chapter 5, is based on a direct gas inlet. The ion source is the part of the mass spectrometer that ionizes the material under analysis (the analyte).

Magnetic or electrical fields (in this. Mass spectrometry (MS) is an analytical laboratory technique to separate the components of a sample by their mass and electrical charge. The instrument used in MS is called mass spectrometer.

It produces a mass spectrum that plots the mass-to-charge (m/z) ratio of compounds in a mixture. Abstract.

To calibrate an anesthetic mass spectrometer without the use of premixed gases and vapors in cylinders, we devised a gas mixer using fixed resistances of capillary needle tubings and adjustable needle valves to dilute test gases and vapors with by: 8.

• Introduction of the evolved gases into the ion source of the mass spectrometer via the interface; • Ionisation of the gas molecules followed by separation and detection of the ions in the mass spectrometer; • Evaluation of the raw data.

Elemental Analyser CO 2 N 2 Interface Mass Spectrometer Carbon dioxide Nitrogen Working GasesFile Size: 1MB. Press the "zero" button to calibrate the spectrometer. Things You'll Need. Reaction solution. To obtain accurate results, keep the cuvette clean and wipe off the sides before placing it into the machine.

: Science, Technology, Engineering, Mathematics. About the Author. Based out of Reno, Nev., Andrew Youngker has been writing. include custom mass spectrometer tuning, time programmed interface splitters, very small injec-tions (), nonlinear curve fitting, and a specialized inlet pressure program [2].

These can be used individu-ally or in combinations to meet the calibration requirements of the ASTM method. However, these. Abstract. A direct air-sampling inlet for a surface ionization mass spectrometer has been developed.

The inlet consists of four elements: (1) a capillary nozzle through which the ambient air is drawn generating a particle beam with small divergence; (2) a ''skimmer'' which skims off the bulk of the air expanding into a vacuum of 1 Torr while simultaneously transmitting the Author: J.J.

Stoffels. A containment facility, with dual inlet systems and a standard distribution system, permits testing with tritium mixtures. Helium flow standards and tritium activity meters provide independent verification of the mass spectrometer calibrations.

A recovery system prevents the release of tritium to the environment. Proton-transfer-reaction mass spectrometry (PTR-MS) is an analytical chemistry technique that uses gas phase hydronium reagent ions which are produced in an ion source.

PTR-MS is used for online monitoring of volatile organic compounds (VOCs) in ambient air and was developed in by scientists at the Institut für Ionenphysik at the Leopold-Franzens University in.

Peterson L. Mass Spectrometer All-Glass Heated Inlet. Analytical Chemistry. ; – Stafford C, Morgan TD, Brunfeldt RJ. A mass spectrometer all-glass heated inlet. International Journal of Mass Spectrometry and Ion Physics.

; –Author: Jens Sproß. sampler cone. This is a water cooled cone with a small orifice, allowing for the hot plasma gas to enter a depressurizing chamber. In this chamber, rapid cooling, and thus rapid expansion, of the gas occurs.

A fraction of this gas then passes through a skimmer cone, and into a chamber that is maintained at a vacuum of that of the Size: 2MB.In working with small samples of CO 2, the automatic cold finger (Figure ) allows cryogenic transfer of the gas sample from an inlet system into the cold finger with liquid nitrogen.

A gas sample as small as m mol can be transferred and. This Varian Saturn GC/MS system comes fully refurbished and tested at GenTech Scientific. The Saturn features: Mass range from 10 to amu, EI Source, Scan range is time programmable throughout the run.

Varian CP GC with Split/Splitless Inlet, Mechanical Pump, Varian Star Data System.5/5(1).